UL94 Horizontal and Vertical Flammability Testing Machine

UL94 Horizontal and Vertical Flammability Testing Machine for Plastic Materials

Product introduction of the Horizontal and Vertical Flammability Testing Machine

Horizontal and Vertical Flammability Testing Machine UL 94 flame chamber. Horizontal flame chamber, vertical flame chamber For the flammability testing of plastic materials used in consumer electric devices and appliances. Stainless steel construction with black interior and large sliding window for easy viewing. Includes a fully adjustable specimen support and precision gas flow controls.

Product parameters of the Horizontal and Vertical Flammability Testing Machine

Timer  0-999.9s+/-0.1s (adjustable)
 Flame Height  20mm+/-2mm to 180mm+/-10mm(adjustable)
 Gas  98% methane
 Temperature testing range  0-1000degree
 Dimensions(L*W*H)  1100 x 700 x 1300mm
 Weight  128kg
 Standards  UL 94-2006 IEC 60695-11-3 IEC 60695-11-4

Product Feature and Application of the Horizontal and Vertical Flammability Testing Machine

Testing Standards 

UL 94-2006 IEC 60695-11-3 IEC 60695-11-4

UL94:Tests for Flammability of Plastic Materials for Parts in Devices and Appliances

UL94HB: Horizontal Burning Test

V-0,1,2: 20mm Vertical Burning Test

94-5VA,B: 500W(125mm) Vertical Burning Test

94VTM-0,1,2: Thin Material Vertical Burning Test

94HBF,94HF-1,2 : Horizontal Burning Foamed Material Test

IEC 60695-11-10:Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods

IEC 60695-11-20: Fire hazard testing - Part 11-20: Test flames - 500 W flame test methods

IEC 60695-11-4:Fire hazard testing - Part 11-4: Test flames - 50 W flames-Apparatus and conformational test method

IEC 60695-11-3:Fire hazard testing - Part 11-3: Test flames - 500 W flames-Apparatus and conformational test method

Product Details of the Horizontal and Vertical Flammability Testing Machine

Kinds  500W(5V class )  50W(HB/Vclass)

Test Flame  500W(burning test for V-0,V-1,V-2 classification)  50W(burning test for V-0,V-1,V-2 classification)

Burner Tube  Internal diameter: Φ 9.5mm±0.3mm  Internal diameter: Φ 9.5mm±0.3mm,

Burning Angle  0°,20°,45°  0°,20°,45°

Thermocouple  Type K (Ni/Cr - Ni/Al)  Type K (Ni/Cr - Ni/Al)

Thermocouple Size  0.5 mm  0.5 mm

Standard Copper Block

9mm±0.01mm,

weight:10g±005g before drilling.

5.5mm±0.01mm,

weight:76g±0.01g before drilling.

Time for Temperature to Increase  From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

From 100°C±5°C to 700°C±3°C;

44s±2s (preset)

Gas Flow  965±32ml/min  105±10ml/min

Gas Supply  methane,min.98% purity  methane,min.98% purity

Water-column 125m±5mm ‹10mm

Test Time  54±2s  44±2s

Flame Height Indicator  40±1mm  20±1mm

Volume Of Chamber  >0.5m³, black interior  >0.5m³, black interior

Conform to standard  UL94,IEC60695-11-3,IEC60695-11-20  UL94,IEC60695-11-4,IEC60695-11-10