Needle Flame Test Chamber

Electronic Product Flame Test Apparatus , IEC 60695 Needle Flame Test Chamber

Product Introduction of the Needle Flame Test Chamber

Needle Flame Test Chamber is used to test the resistance of fire caused by an interior fault such as leakage current in cable & wire and the like. It meets the requirements of Chinese GB4706.1, GB5169.5, and IEC60695-2-2 and IEC61347-1 standards.

Application

Electrical & electronic product

Components and accessories of household appliances

Product  Features of the Needle Flame Test Chamber

a. All stainless steel and brass constructions. b.Burner can be ignited automatically. c.Temperature and test time display by digital meters. d.A big window in the door makes your viewing more convenient.

Product Technical parameters of the Needle Flame Test Chamber

 Needle burner  inner hole diameter Φ 0.5mm ± 0.1mm, Diameter,9mm≤Φ,length ≥ 35mm, stainless steel
 Burner angle  0,°20°, 45° (adjust flame height)
 Thermocouple  Ø0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstandtemperature-40°C~ 1100°C
 Burning time  0-999.9 s ± 0.1 s adjustable (usually selected for 30s)
 Hold Burning time  0-999.9 s ± 0.1 s, automatic recording, manual time-out
 Flame Height  12mm ± 1mm (with height measurement instruments)
 Flame Gas  butane gas/Butane gas, min. 95% purity (can use bottled lighter gases)
 Temperature Test Range  0~1000°C
 Flame Temperature Requirements  from 100 °C ± 2 °C liters to 700 °C ± 3 °C time in 23.5 seconds ± 1 seconds
 Standard Copper Block  4mm±0.01mm, weight.0.58g±0.01g before drilling. Cu-ETP
 Test process  automatic control, independent convulsions
 Chamber  ≥0.5m3
 Control  Using single chip microcomputer + touch screen control
 Consult standard  GB/T5169.10-2006 , IEC60695-11-5:2000,UL746A
 Power Supply  800VA ,220V, 48-60Hz
 Display panel language  English(customize available)